Automatic Kjeldahl Analyzer
4002430
Selecta
12 months
Steam distillation system Kjeldahl, complete with automated “ON-LINE” analysis (evaluation in real time). For systematic precise analysis, with minimum personnel intervention, simple and safe. Adequate for a laboratory with a medium to large throughput of samples.
The Kjeldahl steam distillation unit «PRO-NITRO A» evaluates the distillate at the sa- me time as it is produced ( evaluation «On-Line»), the evaluation and distillation are completed as one operation, reducing drastically the analysis time. This type of eva- luation offers the following additional advantages: detects the point where the sam- ple no longer produces Nitrogen, which means that, the distillation stops at the opti- mum maximum Nitrogen recovery and does not prolong the analysis longer than necessary.
The titration is a colorimetric method and is accepted by AOAC and does not require any periodic calibration.
FEATURES
Distillation by steam generation.
Automatic «On-line» colorimetric evaluation.
Steam generator with safety thermostat, over temperature and over pressure device. Safety, door closed, that prevents distillation if open.
Detects that a digestion/distillation tube is present. This prevents the dosing of NaOH
if there is no tube located.
Universal adapter for MACRO (Ø 42 mm) and MICRO (Ø 26 mm)distillation tubes. Space saving in the laboratory: the reservoirs for the H2O, NaOH, Boric Acid and HCl are located inside the unit.
Empties the digestion/distillation tubes and the collector automatically.
Automatic stop when distillation is complete. Large LCD display of 20 x 4 characters. RS232 output to results printer.
Main system made from stainless steel with an ABS plastic front
SPECIFICATIONS
Measuring range: 0.2 to 200 mg Nitrogen. Nitrogen recovery:> 99.5%
Distillation speed: from 35 to 45 ml/minute
Coolant water consumption: 80 to 100 litres per hour. Steam generator water consumption: 2.5 Litre/ Hr. Steam generator water reservoir capacity: 6 litres. NaOH reservoir capacity: 2 Litres.
Boric Acid reservoir capacity: 2 Litres. Titrant reagent reservoir capacity: 2 Litres. Evaluation precision: 1.5%
Minimum reagent dose 0.01ml.
ALARMS
Low water level for the steam generator.
Safety door open or no distillation/digestion tube in place. Steam generator over temperature.
AUTOMATION
Closing and opening of the condenser cooling water in line with the distillation process. Dosing of Boric Acid.
Dosing of NaOH once the distillation has started. Select NaOH and Boric Acid volume.
«On-line» evaluation of distillate.
Auto detection of the end of the distillation process. Special functions to maximise performance.
Special functions for maintenance.
REAGENTS
All the reagents used in the «PRO-NITRO A» are easily located:
- Solution of 30-40% NaOH.
- Solution of Boric Acid at 1% concentration ( approx.) with mixed indicators
(Bromo-cresol green and methyl red).
- Reagent for titration: HCl or H2SO4 from 0.05N or 0.25N adjusted to 0.001 Normal.
Bình luận
Sản phẩm cùng loại
Freeze Drying Plant Sublimator 50
Freeze Drying Plant Sublimator 50 with 2.4m² shelves, -50°C condenser, 25kg ice capacity
1 x 100L Liter Supercritical Fluid System
Applied Separations, Inc. offers SCF systems in any size and configuration. Although the size of a pilot system versus a production system is arbitrary, customarily, Applied Separations designates pilot systems as having extraction/reaction vessels from 5 liters to 100 liters. Greater than 80 liters, we consider production scale.
Schaller RH2 Portable water activity meter
Schaller RH2 water activity is meter Portable laboratory instrument for determination of water activity (aw value) of food with datalog function. Suitable for measuring materials like butter, fruit mix, spices, granulate, mushrooms, xylit, flour, biscuits or sausage as well as all other food types requiring a check of the water activity value. Furthermore, the humimeter RH2 is suited for measuring special material, e.g. plastic granulate or for climatic and environmental applications.
Lab Oven
The FRANCE ETUVES XU universal ovens are suitable for all applications for drying, heating, heat preservation, sterilization, component aging, curing or any other thermal test in laboratories and in all sectors of industry. There are 8 standard volumes : 32 liters, 58 liters, 112 liters, 225 liters, 343 liters, 490 liters, 686 liters and 980 liters. A forced convection for an amazing temperature homogeneity.
Laboratory Vacuum Oven
Spray Dryer
BII-S151 Spray Dryer The Lab Spray Dryer can convert liquid solution into dry powder automatically in a timely and safely manner. It has many outstanding features including high efficiency, high recovery, minimal sample destruction and loss, easy configuration, simple operation, and continuous drying process. These excellent features greatly extend the potential application fields that are possible with a spray drying process. The material that can be effeciently processed include but not limite