Spray Dryer

Spray Dryer

(2 đánh giá)

BII-S151

BII - Canada

12 months

BII-S151 Spray Dryer The Lab Spray Dryer can convert liquid solution into dry powder automatically in a timely and safely manner. It has many outstanding features including high efficiency, high recovery, minimal sample destruction and loss, easy configuration, simple operation, and continuous drying process. These excellent features greatly extend the potential application fields that are possible with a spray drying process. The material that can be effeciently processed include but not limite

BII-S151 Lab Spray dryer

Origin: Canada

The Lab Spray Dryer can convert liquid solution into dry powder automatically in a timely and safely manner. It has many outstanding features including high efficiency, high recovery, minimal sample destruction and loss, easy configuration, simple operation, and continuous drying process. These excellent features greatly extend the potential application fields that are possible with a spray drying process. The material that can be effeciently processed include but not limited to: natural product solutions, cosmetics, aroma, active pharmaceutical ingredients (API), heat-sensitive biopharmaceuticals, petroleum, etc..

FEATURE
• Touch screen control panel
• Stainless steel enclosure
• Precise temperature control (±1 °C)
• Integrated magnetic stirrer
• Automatic pneumatic nozzle cleaning
• Minimum sample contamination
• Inlet and outlet air filters
• Equipped with secondary cyclone collector
Application
• Food industry: milk powder, coffee, tea, eggs, cereal, spices, flavorings, starch and starch derivatives, vitamins, enzymes, stevia, nutracutical, colourings, etc.
• Pharmaceutical industry: antibiotics, medical ingredients, additives, etc.
• Chemical manufacturing: paint pigments, ceramic materials, catalyst supports, etc.

Drying capacity : 0 ﹣ 25 mL/min (aqueous solution)
Max setting of inlet temperature: 240 °C
Temperature control accuracy: ±1 °C
Sample loading accuracy: 1 %
Max blower flow rate: ~ 500 L/min
Max air consumption: 20 L/min (75 ﹣ 120 psi)
Nozzle size (Diameter): 0.7 mm
Speed range of magnetic stirrer: 0﹣ 1600 rpm
Magnetic stirrer capacity: 20 ﹣ 3000 mL
Power supply: 220V/50 Hz, 16A
Power consumption: ≤ 3000 W
Dimension (cm): L 85 × W 95 × H 165
Net weight: 55 kg

Đánh giá sản phẩm

Bình chọn sản phẩm:

Bình luận

Sản phẩm cùng loại

Freeze Drying Plant Sublimator 50

Freeze Drying Plant Sublimator 50

Freeze Drying Plant Sublimator 50 with 2.4m² shelves, -50°C condenser, 25kg ice capacity

Heat pump dryer GUDO-100T

Heat pump dryer GUDO-100T

Máy sấy lạnh GUDO-100T

Lab and Pilot Heat Pump Dehydrators

Lab and Pilot Heat Pump Dehydrators

Lab and Pilot Heat Pump Dehydrators

1 x 100L Liter Supercritical Fluid System

1 x 100L Liter Supercritical Fluid System

Applied Separations, Inc. offers SCF systems in any size and configuration. Although the size of a pilot system versus a production system is arbitrary, customarily, Applied Separations designates pilot systems as having extraction/reaction vessels from 5 liters to 100 liters. Greater than 80 liters, we consider production scale.

Schaller RH2 Portable water activity meter

Schaller RH2 Portable water activity meter

Schaller RH2 water activity is meter Portable laboratory instrument for determination of water activity (aw value) of food with datalog function. Suitable for measuring materials like butter, fruit mix, spices, granulate, mushrooms, xylit, flour, biscuits or sausage as well as all other food types requiring a check of the water activity value. Furthermore, the humimeter RH2 is suited for measuring special material, e.g. plastic granulate or for climatic and environmental applications.

Industrial Freeze Dryer

Industrial Freeze Dryer

Zirbus Industrial Freeze Dryer
Laboratory Freeze Dryer

Laboratory Freeze Dryer

Zirbus Laboratory freeze dryer VaCo 5
Cold extraction system

Cold extraction system

Cold extraction system Specifically designed unit for cold extraction of up to 6 samples simultaneously, using acetone or other solvents.
Fiber Extraction System

Fiber Extraction System

Fiber Extraction System or Extractor for the determination of cellulose and fibre “Dosi-fiber”
Fat Extractor

Fat Extractor

Fat Extractor or Solvent recovery extractor for fats and oils “Det-gras N”. Equipment for the extraction of fats and soluble substances that will dissolve in solvents. Based on the Soxhlet methods by Randall, the DETGRAS- N extracts fats (and or other substances) from the sample by dissolving them in a solvent. If compared to the classic standard soxhlet method, a time saving of between 30-70% can be obtained due to a two stage extraction process and high speed in obtaining high temperatures.
Automatic Kjeldahl Analyzer

Automatic Kjeldahl Analyzer

Automatic Kjeldahl Analyzer: Steam distillation system Kjeldahl, complete with automated “ON-LINE” analysis (evaluation in real time). For systematic precise analysis, with minimum personnel intervention, simple and safe. Adequate for a laboratory with a medium to large throughput of samples.
Steam distillation unit Kjeldahl Semi-Automatic “Pro-Nitro S”

Steam distillation unit Kjeldahl Semi-Automatic “Pro-Nitro S”

Steam distillation unit Kjeldahl Semi-Automatic “Pro-Nitro S”

Top