Geer's Aging Oven
AG- Series
Ueshima
12 months
Rubber and plastic products will be deteriorated gradually by oxidation or influence of heat and sunlight in a long time of use depending on the environment. Moreover, it may not only result in degradation of the necessary performance which was secured in the beginning but also result in a big accident in some cases. Applicable Standard JIS K 6257, ISO 188, JIS K 7212 B Type/JIS K 7212, ISO 4577
Outline
Rubber and plastic products will be deteriorated gradually by oxidation or influence of heat and sunlight in a long time of use depending on the environment. Moreover, it may not only result in degradation of the necessary performance which was secured in the beginning but also result in a big accident in some cases.
The Geer's Aging Oven is a most popular oven to make the sample in the environment where new heated air is always supplied in a constant rate, thus promoting aging.
The series conform to JIS K 6257 (Rubber, vulcanized or thermoplastic - Determination of heat ageing properties) and/or JIS K 7212 (Plastics − Determination of thermal stability of thermoplastics − Oven method). Each of the four models provides different air exchange rate and chamber size. AG-1100 (analog setting) series and AG-1200 (digital setting) series are different in setting method of air exchange rate.
Feature:
○Most important functions like temperature uniformity, wind velocity and air ventilation rate are in accordance with JIS K 6257 and/or JIS K 7212.
○The minimized shape of the series allows use on a table. We also provide with an exclusive stand.
○It is able to place two units in tiers, minimizing the footprint.
Specification
MODEL |
For Rubber & Plastics |
For Plastics |
|||
Standard |
Large Type |
Standard |
Large Type |
||
(*1) |
Analog Setting |
AG-1110 |
AG-1115 |
AG-1120 |
AG-1125 |
Digital Setting |
AG-1210 |
AG-1215 |
AG-1220 |
AG-1225 |
|
Applicable Standard |
JIS K 6257, ISO 188, JIS K 7212 B Type |
JIS K 7212, ISO 4577 |
|||
Chamber Dimensions (mm) |
W450 x D450 x H500 |
W600 x D600 x H600 |
W450 x D450 x H500 |
W600xD600xH600 |
|
Chamber Material |
Stainless Steel (SUS 304) |
||||
Temperature Range |
40 to 300ºC |
||||
Temperature Control |
Temperature controller with digital display, PID with auto tuning |
||||
Temperature Sensor |
Resistance thermometer bulb (Pt100Ω, 3.2-mm dia. x 350mm) |
||||
Temperature Sensor |
Platinum resistance temperature detector |
||||
Pt 100Ω,φ3.2 x250(L) |
Pt 100Ω,φ3.2 x300(L) |
Pt 100Ω,φ3.2 x250(L) |
Pt100Ω,φ3.2 x300(L) |
||
Heater |
1-ph 200V, 3kW |
3-ph 200V, 6kW |
1-ph 200V, 3kW |
3-ph 200V, 6kW |
|
Circulation Fan Motor |
200VAC, 0.2kW |
||||
Temperature Rising Time |
Within 45 min. from RT to 300ºC |
||||
Temperature Uniformity |
Within ±1ºC (40~100ºC), ±1% (at 100 ºC or higher) |
||||
Average Wind Speed |
0.5±0.1m/sec(*2) |
1.0±0.2m/sec(*3) |
|||
Ventilation Rate |
3 to 10 times/hour (variable) (*2) |
5 to 60 times/hour (variable) (*3) |
|||
Sample Hanger Rotation |
6~8 rpm |
||||
Safety Device |
(a) Leakage breaker: protection of short circuit, overcurrent (b) Overheat protector: default set to 325ºC, causes power shut down (c) Overload protection of circulation fan motor |
||||
Accessories |
Single shaft two stage sample hanging frame, sample clip, glass fuse |
||||
Power Supply Required |
1-ph 200VAC, 20A 50Hz or 60Hz |
3-ph 200VAC, 30A 50Hz or 60Hz |
1-ph 200VAC, 20A 50Hz or 60Hz |
3-ph 200VAC, 30A 50Hz or 60Hz |
|
Outer Dimensions (mm) |
W1050x D720xH860 |
W1250xD910xH990 |
W1050xD720xH860 |
W1250xD910x H990 |
|
Option Stand(mm) |
optional shelf board, optional exclusive stand(H:835mm(Standard),825mm(Large Type)) |
Bình luận
Sản phẩm cùng loại
Mooney Viscometer
Ueshima Seisakusho VR-1130 Mooney Viscometer ●Measurement of Mooney viscosity for unvulcanized rubber ●Measurement of scorch time for unvulcanized rubber Applied Standard JIS K 6300-1, ISO289, ASTM D 1646
Constant-stress/strain flexometer
Rubber, vulcanized — Determination of temperature rise and resistance to fatigue in flexometer testing: Constant-stress/strain flexometer. This machine determines change in complex modulus of elasticity E', E", tan6 and heating rate of rubber during the thermal fatigue process. Standard: ISO 4666, JIS K 6265,...
Rotorless rheometer (Flat Die Rheometer)
JIS K6300-2, ISO 6502, ASTM D 5289 (Oscillating Sealed Flat Die Cavity Rotorless Curemeter) FDR (Flat Die Rheometer), manufactured by Ueshima Seisakusho Co., Ltd.
GEHMAN’S TORSION TESTER
Rubber loses resiliency as temperature goes down. The frozen rubber can't keep its essential characteristics under the temperature below Glass Transition Point. In fact, the rubber applications under severe environments such as vehicle tire in frozen area and aircraft components in the stratosphere are seriously affected. Our Gehman's torsion tester TM-2535 is the most popular testing machine for this purpose and is adopted by JIS K6261(Equivalent to ISO 1432, ASTM D1053).
DIN Abrasion Tester
The DIN Abrasion Tester is of the type that rotates a drum with grinding cloth wound around the surface at a specified speed, presses the sample against the grinding cloth. Applicable Standard: JIS K 6254-2/ISO4649/ISO23794 Test Piece Size: 16.2±0.2mm dia, 6mm or thicker Drum Size: 150±0.2mm dia., 460mm wide Drum Speed: 40±1rpm