Kesternich Corrosion Chamber – SO2
KEQ 300
Equilam N.A. - USA
12 months
The corrosion chambers type SO2, KEQ series, also known as Kesternich chamber, were built to meet the requirements of ASTM, DIN, DIN EN ISO, others. Contact Us: Email: secovina@vnn.vn OR Mr. Felipe Rojo, Email: frojo@equilamna.com
Kesternich Corrosion Chamber – SO2
The corrosion chambers type SO2, KEQ series, also known as Kesternich chamber, were built to meet the requirements of ASTM, DIN, DIN EN ISO, others.
The following construction characteristics of the equipment are very important for repeatability and reproducibility of each test, These tests are comparative, so they must follow the exact construction characteristics of the standards.
– Angled lid/ceiling with a smooth internal finish to avoid dripping on the samples.
– SD Card, saved in real time test parameters, just open Microsoft Excel to display the chart of every cycle, only KEQ 300.
– Construction according to UL508.
– All components used are UL listed.
– Internal volume of 300 liters of usable space.
– Equipment is constructed with inert materials that do not interfere in the final result of the test.
– Touch Screen
– SO2 dose controller, electronic, allowing dosages 25 ml up to 6000 ml.
Application:
The chambers are used to perform rapid acid and wet acid corrosion tests on metal parts with organic or inorganic coatings.
Its application primarily serves companies in the automotive, civil construction, plastic, aviation, oil and gas, paints, varnishes, electronics, chemical, metallurgical and other related industries.
Operation:
The test samples are arranged within the test cabinet according to technical standards. They are exposed to an acidic atmosphere (H2SO4) and wet at a temperature of 40°C for 8 hours and then enter a cooling mode with circulating air controlled for 16 hours where the internal temperature of the chamber will reach the ambient temperature of the laboratory. We usually recommend a laboratory temperature of 23°C +/- 3°C. This 24-hour period is called the round (end of the test). Normally the number of rounds should be agreed upon between the customer / supplier.
Main test standards:
ASTM G 87 – DIN 50018 – DIN EN ISO 6988-2 – ISO 3231.
VW Corporate Rules – Mercedes Benz – other consult us.
Built in fiberglass with special resin of high chemical and temperature resistance (Inert Material – DIN 50018 / ASTM G87/ ISO 6988-2 / ISO 3231), externally and internally.
US PATENT # 10371623
Control Panel: PLC (Programable Logical Controller) with colored touch screen of 5.7”;
DEI water tray built with inert material (nonmetallic), volume: 0.52 gal (2 L), included security system to lack of water on the tray and overheating. Cooling by air circulation.
Frontal door in accordance to technical such as tempered glass standards.
8 round bars specimens support of 12 mm of material nonmetallic.
Electronic SO₂ dosing device with high precision;
Supervisory Software – for data acquisition, 2 types (options): Via RS 232, 485, USB, Ethernet needs a PC connected full time.
Automatic cycle in accordance to the below standards: DIN 50018, ISO 6988-2, ASTM G 87, ISO 3231
-
Internal cabinet in fiberglass without metallic parts, ensuring test performance
-
Allows visualization of programmed mode and the performed modes, records and shows date and hour of executed alarms
-
Loops Program: 20 modes, with repetitions of 100 times for each program
-
Events: outputs ON/OFF – 220 Volts – 5 Amp – (to perform dynamic tests – optional)
-
Resolution: 0,1ºC
-
Scan tax: 30 milliseconds maximum
-
Auto Tuning independent for each mode
-
Control System of temperature and relative humidity P.I.D (Proportional Integrative Derivative) independent for each mode and mode ramp to attend the standard
-
Function preventive maintenance, to avoid not programmed stops
-
Function scheduling with date and hour to start the test
-
Function Graphic with a single touch on the panel allows the operator to visualize graphically the parameters of test on line on the touch screen
-
Timer with indication of time of test and time of interruption
Selection on display of unit of temperature °C or °F;
TECHNICAL INFORMATION
-
Cabinet internal temperature Range: Amb. + 9°F(+5°C) - +140°F(+60°C)
-
Ambient temperature for chamber’s installation: +62°F(+17°C) - +82°F (+28°C) - Max. 85% R.H (without condensation)
-
Homogeneity of the internal cabinet temperature: ±1.8°F (±1°C)
-
Relative humidity of the internal cabinet: 97% - 100%
-
SO₂ dosing: 0.006604 gal to 1.585 gal (25 ml to 6.000 ml)
-
DI water tray volume: 0.52 gal (2 L)
-
Electrical Supply: 208 to 220 Vac Ø1 60 Hz – 10 FLA (other consult factory)
-
Volume of internal test cabinet: 79.3 gal (300 L)
-
Approx. net weight: 143 lbs. (65 kg)
-
Approximate Shipping Weight (Crated): 309 lbs. (140 kg)
-
Internal dimensions L x W x H: 28” x 20” x 35.3” – 29.9” (720mm x 510mm x 890 – 760mm)
-
External dimensions L x W x H: 43.3” x 36.2” x 77.9” (1100mm x 920mm x 1980mm)
OPTIONAL ACCESSORIES
CODE: EQOP.0006 |
|
|
CODE: EQOP. 0150 |
|
|
|
|
|
CODE: EQOP.0113 (For 2 Chambers) |
Composed of doors, wall in fiber glass, fan 130.66 CFM in fiber glass and |
|
|
fume hood in fiber glass smooth of two sides. |
|
|
W x D x H: 99.6”x 74.9”x 114.2” |
|
|
(2,530 x 1,900 x 2,900 mm). |
|
|
Door: two-way door |
|
|
(2) 27.6”x 74.9” ((2)700 x 1,900 mm) |
CODE: EQOP.0113 |
|
|
(For 1 chamber) |
Composed of doors, wall in fiber glass, fan 130.66 CFM in fiber glass and |
|
|
fume hood in fiber glass smooth of two sides. |
|
|
W x D x H: 63.0” x 49.2” x 114.2” |
|
|
(1,600 x 1,250 x 2,900 mm). |
|
|
Door: two-way door |
|
|
(2) 27.6”x 74.9” ((2)700 x 1,900 mm) |
|
|
Part List item 3.1 |
|
CODE: EQOP.0112 |
|
|
CODE: EQOP.0152 |
|
|
CODE: EQOP. 0037 |
|
|
|
|
|
CODE: EQOP.0076 |
/ ISO 6988-2. (100 Pieces). |
|
CODE: EQOP.0077 |
|
|
CODE: EQOP. 0047 |
|
|
CODE: EQOP.0054 |
|
|
CODE: EQOP.0055 |
volume + pressure regulating valve with 02 pressure gauge in 316 stainless steel. |
|
RECOMMENDATED LABORATORY FACILITIES
DI water: 0.52 gal (2 L) per 24 hours cycle
Electrical Supply: 208 to 220 Vac Ø1 60 Hz – 10 FLA (others consult factory) Water Supply: Chamber cleaning
Water to be per ASTM D 1193 Type IV standard
Exhaust: Air room from where equipment will be installed Drain: 4” tubing (must be drained to sewage treatment)
Recommendation of the corrosion laboratory - SO2 - Kesternich Test Chamber
(One) Year Parts Warranty against manufacturing defects from date of delivery at customer's site. This assumes equipment is used under normal operating conditions in accordance to the instruction manual. This warranty does not apply to glassware (lamps). In case of non-warranty issues during warranty period, actual expenses shall apply.
Note 1: All our equipment is delivered with Installation, Maintenance and User Manuals. We believe this material is enough for the correct use of the equipment. We are available for further questions and clarifications. If necessary, we provide the service of assembling and staff training at client’s site (Cost for this service available upon request).
Note 2: Appearance and specifications of equipment are subject to change without prior notice
Bình luận
Sản phẩm cùng loại
Salt Spray (Salt Fog)
Salt Spray (Salt Fog) – ASTM B117 / ISO 9227 / JIS Z 2371 / ASTM G85 A1. This is the traditional technique to simulate corrosion in the laboratory, widely used to perform rapid corrosion tests on metal parts with organic or inorganic coatings. Its application mainly serves companies in the automotive, renewable energy, construction, plastics, aviation, oil and gas, paints, varnishes, electronics, chemical, metallurgical, and other industrial sectors.
Cyclic Corrosion Test (C.C.T)
The EQUILAM NA C.C.T Cyclic Corrosion Test chambers provide the best simulation for accelerated corrosion testing. Some studies indicate that the tests results closely resemble those obtained in outdoor exposure. Samples can be exposed to different environmental conditions. Contact Us: Email: secovina@vnn.vn OR Mr. Felipe Rojo, Email: frojo@equilamna.com , Phone: 1.754.900.7816
Cyclic Corrosion Test CORR Auto
The EQUILAM NA CORR AUTO model cyclic corrosion test chambers provide one of the most realistic simulations for accelerated corrosion testing. Some studies indicate that the test results closely resemble those obtained in outdoor exposure. Contact Us: Email: secovina@vnn.vn OR Mr. Felipe Rojo, Email: frojo@equilamna.com , Phone: 1.754.900.7816
Water Resistance Test Chamber – Humidity Test
Water Resistance Test Chamber – Humidity Test to ASTM D1735 / ASTM D2247 / DIN 50017 / ISO 6270-2.
Contact Us: Email: secovina@vnn.vn OR Mr. Felipe Rojo, Email: frojo@equilamna.com , Phone: 1.754.900.7816 .
Gravelometer / Stone Chip Resistance Test
The Gravelometer, or Chipping Resistance Tester, is designed to rigorously meet the technical standards of ASTM D3170, SAE J400, ISO 20567-1, DIN 55996-1, and VDA. For other standards, please contact us. Contact Us: Email: secovina@vnn.vn OR Mr. Felipe Rojo, Email: frojo@equilamna.com , Phone: 1.754.900.7816 .
Accelerated Weathering Tester – UV
The accelerated weathering test simulates the atmosphere with sunlight (UV mode), dew (condensation mode), rain (thermal shock) and rain + UV (thermal shock and UV). The test results are reliable, fast and comply with the technical standards ASTM D4329, ASTM G154, ASTM G151, ASTM G53, SAE J2020, ISO 4892-3, among others. Contact Us: Email: secovina@vnn.vn OR Mr. Felipe Rojo, Email: frojo@equilamna.com , Phone: 1.754.900.7816 .
IPX9K Code
IPX9K Code Test Chamber Standards : ISO 20653, IEC 60529. Contact Us: Email: secovina@vnn.vn OR Mr. Felipe Rojo, Email: frojo@equilamna.com , Phone: 1.754.900.7816
Dupont Impact Tester
Dupont’s Impact Tester is used to measure the resistance of specimen (painted plate, hard plastic sheet, etc.) against impact force by observing the appearance of crack and peeling.
Solids Density Meter
Solids Density Meter
Application:rubber,plastic,cables,hard alloy,glass,new materials researching laboratory.
Standards:According to ASTM D792,GB/T1033,GB/T2951,JIS K6268,ISO 2781,ISO 1183,GB/T208,GB/T5163,GB/T 1933 standards etc.
DH300 is one of the densimeter that have been widely applying to industry,using water as medium,the density value can be displayed after two steps.Compared with traditional densimeter,there is no calculation by hand,which is more convenient.
Flexometer
The Constant Stress/Strain Flexometer measures the heating characteristics of a vulcanized rubber test piece when applied test amplitude the load(stress)controlling to a specified level applying to static load.It also performs tests by controlling a specified deflection(strain).Unlike conventional flexometers,this equipment adopts a special temperature detector to measure the inner temperature of a test piece during testing,thus making it possible to measure the real heat-up temperature.The test
Internal Mixer
CT Internal Mixer is suitable for many applications:
- Polymer and/or rubber compound.
- Polymer and/or rubber composite.
- Polymer and/or rubber blend.
- Food and food product i.e. starch modification.