Supercritical Fluid Extraction

Supercritical Fluid Extraction

(10 đánh giá)

OV-SCF-10000C

TST - Taiwan

12 months

The OV-SCF-10000C is the entry-level SFE in our series of instruments for supercritical fluid processes. This no-frills machine satisfies the rigorous needs of research in the lab with a price tag that allows everyone to take advantage of the benefits of Supercritical fluids.

OV-SCF-10000C Oven Extraction Equipment 

A. System Requirement

1. Power supply: 220V, 10A

(Include B-1. OV-SCF: Extraction Oven & B-2. PM-10000C: Digital Pressure Control Module)

2. Driven air: compressed dry air or general air (6~8 kg/cm²)

3. Cooling water: ≤5°C

4. LCO₂ supply

B. Detail Specifications

B-1. OV-SCF: Oven Extraction Furnace

1. Operation temperature: room temperature ~220°C (max).

2. Temperature control: heating rate ≥10°C

3. Output pressure: 1500 ~ 7250 psi

4. Operation capacity:

o High-pressure extraction vessels with size ranging of 60ml, 250ml, and 1.0L can be installed in OV-SCF and exchanged as needed.

5. High Pressure Extraction Vessel: 1 Liter

6. Double extraction loop: capable of 2 extraction set.

7. Extraction mode: continuous or batch extraction.

8. Cleaning method: capable of solvent injection device.

9. Flow control: tunable control with display of gaseous CO₂ flow rate.

10. Certification: IEC61010-2-010 (2nd Ed) for use with IEC61010-1:2001, certificate number: 97-0768.

11. Power supply: 220V, 10A

 B-2. PM-10000C: Digital Pressure Control Module

1. Output pressure of system: 1500~7250 psi (depends on pressure of gas source).

2. Pneumatic pump

a. Output pressure: MAX 7250 psi.

b. Flow rate: 200 ml/min (under 4350 psi).

3. Heat exchanger inside (not include water chiller).

4. Safety protection system

a. Alarm of over-pressurization.

b. Alarm of operating timer.

c. Emergency stop and automatic gas-cut device for over-pressurization.

d. Pressure relief valve (full port type).

5. Touch panel control system.

6. Certification: IEC61010-2-010 (2nd Ed) for use with IEC61010-1:2001, certificate number: 98-0192.

7. Embedded communication Prot (USB/RS232) to support output device (printer).

8. Power supply: 220V, 1A

 C. Water Chiller

1. Power supply: 220V, 7A

2. Operation temperature: -20°C ~40°C (max).

3. Temperature control: PID Automatic Algorithm.

4. Recycle Pump: SUS recycle pump.

5. Pump flow rate: 8L/min, 0.2kg/cm²

6. Compressor: 1/3Hp, 750Kcal/hr

7. Capacity: 10L

 ESP-010B: Co-solvent pump

1. Flow rate: 0.01 ~ 9.99 ml/min

2. Display: LED digital display

3. Pressure: Max 5500 psi

4. Pump: SUS316

5. Accuracy: ±2%

6. Precision: ±0.2%RSD

7. Digital flow rate setting

8. Configure check valve

9. Dimension: 415 x 297 x 330 mm

10. Power supply: 220V / 1A

11. Pipeline: 1/8” seamless stainless steel pipe

12. Safety device: safety valve (Setting pressure: 5500 psi)

13. High pressure needle valve

14. Analogical pressure gauge

 Vessels:

1. Volume: 60 ml

2. Operation Pressure: 500 Bar (max)

3. Operation Temperature: 200°C (max) 

4. Upper and lower cover design of the vessel

 

 1. Volume: 250 ml

2. Operation Pressure: 500 Bar (max)

3. Operation Temperature: 200°C (max)

4. Upper and lower cover design of the vessel

 1. Volume: 1000 ml

2. Operation Pressure: 500 Bar (max)

3. Operation Temperature: 200°C (max)

4. Upper and lower cover design of the vessel

 

Power System

1. Power: 4.5 HP

2. Working Pressure: 0 ~ 8 Kg

3. Tank Volume: 60 L

4. Voltage: 220V / 50Hz / 13A

5. RPM: 1720

6. Displacement: 360 L/Min

7. Weight: 38 Kg

8. Dimension: 67 x 33 x 75 cm

Đánh giá sản phẩm

Bình chọn sản phẩm:

Bình luận

Sản phẩm cùng loại

Supercritical Fluids Extraction

Supercritical Fluids Extraction

TST Model SE-600–10000 Supercritical Fluids Extraction Machine

SE-2000–10000 Series supercritical fluid extraction

SE-2000–10000 Series supercritical fluid extraction

The TST Model SE-2000–10000 Series Supercritical Fluid Preparative scale CO2 extraction Equipment

SCCO2 5L Extraction Equipment

SCCO2 5L Extraction Equipment

SE-051 Series Supercritical CO2 System Custom 5L System (SCCO2 5L Extraction Equipment)

20/40 Liters Supercritical Extraction Systems

20/40 Liters Supercritical Extraction Systems

TST -Taiwan Supercritical Technology Co., Ltd. offers SCF systems in any size and configuration. Although the size of a pilot system versus a production system is arbitrary, customarily, TST designates pilot systems as having extraction/reaction vessels 20 liters and 40  liters.

Ultrasonic 17L Lab Extraction Equipment

Ultrasonic 17L Lab Extraction Equipment

Ultrasonic 17L Lab Extraction Equipment Model : ES-600N, Manufacturer : TST - Taiwan : Ultrasonic extraction technology can reduces processing time and solvent use, thus to obtain higher extraction rate and more healthy extract.

Ultrasonic 100L Extraction Equipment

Ultrasonic 100L Extraction Equipment

Ultrasonic 100L Extraction Equipment Model : UL-100E ( 100 L) , Manufacturer : TST - Taiwan : Ultrasonic extraction technology can reduces processing time and solvent use, thus to obtain higher extraction rate and more healthy extract.

Top

  Zalo